Inverting Settings
SETTING NAME FACTORY VALUE DEFAULT VALUE
Inverter Output Voltage 240.0 Vrms 240.0 Vrms
Large Transformer Output Ohms 0 0
Tap Transformer Output Ohms (not
used)
00
Small Transformer Output Ohms 0 0
Maximum Inverter Current 18.75 Arms 18.75 Arms
Maximum Inverter Surge Current #1 28.13 Arms 28.13 Arms
Maximum Inverter Surge Current #2 37.50 Arms 37.50 Arms
Maximum Inverter Surge Current #3 56.25 Arms 56.25 Arms
Small Inverter / Load Demand Ramp
Up/Down
13 Cycles 4 Cycles
Small Inverter / Load Demand Exit 80 Watts 80 Watts
Small Inverter / Load Demand Start 75 Watts 75 Watts
Small Inverter / Load Demand Tail 5 S 5 S
Small Inverter / Load Demand Delta 1 S 1 S